??金鲨银鲨??

SITEMAP XMLMAP Free service hotline: 400-820-2085 / 021-69899777 SITEMAP XMLMAP

Tips for using fluoroplastic magnetic pump

Since the introduction of fluoroplastic magnetic pumps , it has gained wide favor because of its strong corrosion resistance. How to correctly use fluoroplastic magnetic pump has also become a topic of discussion for many users. Here are some references for reference based on the product characteristics of Shanghai Chaole Magnetic Pump Manufacturing Co., Ltd.

Fluoroplastic magnetic pump should be inspected before use, such as checking whether the motor's rotation direction is consistent with the magnetic pump's turning mark; whether the motor blades are rotating flexibly, and whether the magnetic pump, pipelines and joints are loose. Unscrew the drain plug of the pump body of the fluoroplastic magnetic pump and pour the drainage. Close the gate valve, outlet pressure gauge and inlet vacuum gauge of the outlet pipe. Then jog the motor to see if the motor is turning correctly. When the motor is started, the discharge valve should be slowly opened. After the fluoroplastic magnetic pump enters the normal working state, adjust the discharge valve to the required position. When the fluoroplastic magnetic pump is running normally, open the outlet pressure gauge and the inlet vacuum pump. After the suitable pressure is displayed, gradually open the gate valve and check the load of the motor at the same time. During use, try to control the flow and head of the fluoroplastic magnetic pump within the marked range to ensure that the fluoroplastic magnetic pump operates at the highest efficiency point and can obtain the best energy saving effect. Before the fluoroplastic magnetic pump stops working, the discharge valve should be closed first, and then the valve of the suction pipe should be closed. Monitor the condition of lubricating oil and stuffing box frequently during work, replace or replenish the bearing lubricating oil in the bearing body in time, and use new packing after replacing the stuffing box.

I hope the above introduction by Xiaobian will give you a more detailed understanding of the use of fluoroplastic magnetic pumps !

This article is contributed by Shanghai Chaole Magnetic Pump Manufacturing Co., Ltd. Welcome to the interactive communication of relevant persons in the magnetic pump industry.

National Service Hotline: 021-69899777 69898777 Fax: 021-67868886 Email: chaole655@163.com

Shanghai Public Network Security Preparation No. 31011402001401 Copyright ? Shanghai Chaole Magnetic Pump Manufacturing Co., Ltd. All Rights Reserved 沪 ICP 备 11030557 号 -1

822799384

910058260

Service Hotline

021-69899777 021-69898777

Functions and features

Prices and offers

WeChat consulting

七乐彩 欢乐拼三张 欢乐拼三张 天天电玩城